The MR388 Series extends the usefulness of the Fiber Optic E-Stop System by providing a turn-key solution where a protective, weatherproof cabinet is required. This solution can be installed indoors or outdoors. The multi port options allow fiber optic cable to loop through unit via conduit or ODVA IP-LC connections. The MR388 series is available for use with either multimode OM1 62.5/125 (compatible with OM2/OM3 50/125) or singlemode OS1 fiber. This products support all manner of installations in hazardous environments or over long distances.
The MR387 E-STOP is designed for applications where a system needs to be deactivated when the E-STOP switch sensor is depressed or any system malfunction occurs. The fiber optic aspect of the system provides immunity to EMI/RFI, magnetic fields, RF fields, high voltage isolation – and able to traverse long distances up to 10km,
The FO E-Stops can be arranged in different ways, click on the following diagrams for more information:
Specifications
Functionality | |
ISO 13850 | ISO 13850 defines the characteristics and requirements for a traditional electromechanical E-STOP switch. The MR387 Sensor/Controller integrates the definition of purpose and functionality only. |
ISO 13849 | Category 2 for MR380/MR387 E-STOP Sensor/Controller System |
Functional Safety | Consult Declaration of Conformity for additional F.S. information |
Classification | MR387 Sensor/Controller System = Category 2 per ISO 13849-1 |
MTTFd | 4.14 E+06 hours (473.1 years) |
Performance Level | PL=c |
Safety Integrity Level | SIL=1 |
Functional States | MR380 Controller Output States |
Normal RESET (Up Position) |
Red LED is OFF Digital 5V and 24V Outputs=HI Relay NC contacts=Closed, Relay NO contacts=Open |
ACTIVATED (Down Position) Broken Fiber, Loss of Optical Signal, or Controller Failure |
Red LED is ON Digital 5V and 24V Outputs=LOW Relay NC contacts=Open, Relay NO contacts=Closed |
Optical Interface | > |
Interface | Duplex LC for pigtailed sensors, MR387-X-YY where YY is pigtail length in meters ODVA IP-LC connector receptacle, MR387-X-D00 sensors in housing |
Insertion Loss |
MR387-2-XX, 2.5 dB (2 dB Typical), LC-Duplex Pigtail, 62.5/125μm OM-1 MM Fiber MR387-3-XX, 5.0 dB (3 dB Typical), LC-Duplex Pigtail, 9/125μm OS-1 SM Fiber MR387-5-XX, 3.5 dB (3 dB Typical), LC-Duplex Pigtail, 50/125μm OM-2 MM Fiber Consult Application Note AN118 for guidance on determining system loss budget and maximum distance of single and multiple E-Stop networks. |
Explosive Atmospheres | Inherently Safe, Simple Mechanical Device |
EX Classification |
Inherently safe, simple mechanical device when used with MR380 Controller IECEx Test Report GB/CML/ExTR 16.0105.00/00 |
ATEX | EPL Mb/Gb/Gc/Db/Dc |
EAEU/GOST | EPL Mb/Gb/Gc/Db/Dc |
IEC Ex | EPL Mb/Gb/Gc/Db/Dc |
North America | Exempt, non-electrical |
Environmental | |
Temperature/Humidity | -40°C to +65°C (-40°F to +150°F), 0-95% RH, Non-Condensing |
Ingress Protection | IP66 |
Mechanical | |
Housing | Polycarbonate housing with clear cover and manual latch |
Durability | 100,000 operations min. |
Physical | |
Housing Dimension | Consult Mechanical Reference Drawing |
Mounting | Consult Mechanical Reference Drawing |
Unit Weight | TBD |
Specifications subject to change without notice
Features
- Sensor is EX classified “Inherently safe, simple mechanical device”
- Sensor can be operated in any hazardous or explosive environment – gas, dust or mines
- Immune to EMI, RFI, lightning, and ground loops
- Immune to high voltage lines
- Panel mountable sensor
- DIN rail mountable controller
- Controller provides DPDT relay and digital signal outputs
- Operates over long distances – up to 10km (6 miles) with single mode fiber
- Multiple E-STOP switches can be connected in series
- Contact Micronor sales regarding our POF E-Stop
TO ORDER
Call +1-805-389-6600 or email sales@micronor.com
Ordering Information
MR388-X-Y-Z | Fiber Optic E-Stop in Cabinet Housing: where X=Fiber type: 0=OM1 62.5/125 MMF, 1=OS1 9/125 SMF where Y=Mushroom Button Size: 0=Small=30mm OD, 1=Medium=40mm OD where Z=Interfaces: 0=Single ODVA IP-LC port, 2=Dual IP-LC ports; 1=Single 1/2″ NPT Conduit Hub, 3=Dual Conduit Hubs |
MMF=Multimode Fiber, SMF=Single Mode Fiber
Quick Ship Configurations
MR380-0-UNI | Universal SM/MM OEM E-Stop and Switch Controller |
MR380-1-3 | Universal SM/MM DIN Rail Mount E-Stop and Switch Controller Module |
MR388-0-0-0 | E-Stop Sensor for OM1 62.5/125 MMF, 30mm OD Mushroom Button, Single IP-LC interface |